- Opening speed approx. 0.8 sec
- The lock can always be operated with a cylinder / knob
- Built-in door position sensor that can be supplemented with or replaced by an external one
- Hold time 4 – 64 seconds
- Available in 25 or 35 mm mandrel depth
- The DAC630 control unit functions as an interface to the outside world, e.g. passage or alarm system
- Works as an interface to the outside world, to systems without Hi-O bus, e.g. access or alarm systems
- Communicates with Hi-O products via Hi-O bus
- Provides indications to the superior system that tell the status of the lock and the door
- Enables completion with external door position sensor (magnetic contact)
- Also controls supplementary day lock, i.e. a complete day/night combination is formed
- Activates alarm output in case of malfunction
- Connects to voltage supply
- If the DAC630 is integrated with the ARX access system, a fully integrated solution with great flexibility is created
- Technical data Voltage 24 VAC / VDC ± 15
- Current consumption rest 150 mA max 400 mA
- Relays Single-pole switching Max. 50 VDC, 1 A
- Connection cable EA226 10 m, maximum distance between motor lock and control unit 50m.
- Door opening max. 6 mm
- Engine lock Temp – 40°C – +70°
- Control unit Temp + 5 °C – + 40°C
- Humidity 20-90% relative non-condensing