This one wireless heat and carbon monoxide (CO) detector is developed to provide reliable and early protection against fire and dangerous CO gases in homes and premises. The detector is intended for indoor installation and is equipped with both built-in siren and clear LED indication for immediate warning in the event of an alarm.
Protection against both heat and carbon monoxide
Unlike traditional smoke detectors, this detector reacts to:
-
Rapid temperature increase or high temperatures
-
Dangerous levels of carbon monoxide (CO)
In the event of an alarm, the built-in siren (85 dB) is activated and the LED indicator lights up red for a clear visual warning.
Interoperable alarms throughout the system
The detector can be configured to all smoke, heat and CO detectors in the system alarm simultaneously when a detector is activated. This provides a loud and clear alarm throughout the building, even if a fire or CO emission occurs in another room.
Self-test and high operational reliability
For maximum safety, the detector performs regular self-tests and automatically notifies you about:
-
Sensor error
-
Low battery level
-
Functional abnormalities
This minimizes the risk of a detector not working when it is really needed.
Works even without an alarm system
The detector can be used independent, just like a regular smoke detector, making it flexible in both alarmed and non-alarmed environments.
Long service life and low maintenance cost
-
Up to 7 years battery life with replaceable batteries
-
10 year lifespan of the CO sensor
-
Wireless range up to 1700 meters in open terrain
Technical specifications
-
Type: Wireless heat and CO detector
-
Area of use: Indoor
-
Compatibility: Hub Plus, Hub 2, Hub 2 Plus, Hub Hybrid, ReX, ReX 2
-
Wireless range: Up to 1700 m (open terrain)
-
Battery: 2 × CR123A
-
Battery life: Up to 7 years
-
CO sensor lifespan: 10 years
-
Temperature range: 0°C to +50°C
-
Maximum humidity: 80 %
-
IP class: IP20
-
Volume: 85 dB (at 3 m)
Alarm thresholds – heat
-
+64 °C
-
Temperature increase ≥ 10 °C in less than 1 minute
Alarm thresholds – carbon monoxide (CO)
-
50 ppm (0.005 %): alarm within 90 min
-
100 ppm (0.01 %): alarm within 40 min
-
300 ppm (0.03 %): alarm within 3 min