ABLOY analog motor locks EL575 are adapted for doors with modular recesses. Suitable as night and security locking in doors with high security requirements in commerce, offices and industry. Day-locked or high-frequency doors should be supplemented with a day lock, e.g. electric push lock ABLOY EL580.
Accessories included in the kit package:
Motor lock EL575, control unit EA452. end plate EA342. connection cable EA224 (10m), cable transfer EA281.
Characteristics
- Opening time approx. 0.7 seconds.
- The lock can always be opened with a key / knob.
- Built-in door position sensor (magnet), which can be replaced by an external magnet.
- Hold time 2-15 seconds.
- The rule is driven by the built-in motor A
- ABLOY EL575 without pressure drop can be used in doors with door automation
- Each motor lock requires a control unit (EA452) that manages the communication between the motor lock and the outside world.
The control unit EA452
- Functions as an interface to the outside world, e.g. passage or alarm system.
- Communicates with the engine lock.
- Requires control signals from parent system to operate engine lock.
- Provides indications to the superior system that tell the status of the lock and the door.
- Connects to voltage supply.
- Can be supplemented with backup cards that lock or unlock in the event of a power failure. - NOTE! Backup cards are NOT a certified emergency or panic evacuation feature.
- Must be installed indoors on the protected side of the door within 15m of the motor lock.
Technical data
- Voltage: 12 – 24 VDC ± 15 %, alt. 12-18VAC – 10 % – + 15 %
- Current: 12 VDC, rest 70 mA, max 300 mA,
- Current: 24 VDC, rest 35 mA, max 150 mA
- Relays: Single-pole switching Max. 30 VDC, 0.8 A
- Max. distance between motor lock and control unit 15 m.
- Door gap: max. 5 mm.
- Engine lock: Temp – 20°C – +60°C
- Controller: Temp + 5 °C – + 40 °C, 20 – 90% relative humidity, non-condensing