Time Relay 6-30V Programmable with LCD Display
This advanced time relay module from Sinilink is ideal for automation projects where precise time control is required.
It is equipped with a clear LCD display, wide voltage compatibility and support for multiple working modes as well as cyclic functions.
Properties:
-
LCD display clearly shows current operating status and set parameters.
-
Support for both high and low level triggering as well as control via switches.
-
Wide input voltage range: 6ā30V, also supports 5V via micro USB.
-
Support UART data transmission and parameter setting.
-
Emergency stop with STOP button and protection against incorrect polarity.
-
Power saving mode: if no button is used within 5 minutes, the backlight will turn off automatically.
-
Independent OP, CL and LOP parameters can be saved separately.
-
All settings are automatically saved in the event of a power outage.
-
Industrial-grade construction with optocoupler isolation for increased interference immunity.
Specifications:
-
Working voltage: 6ā30V
-
Time interval: 0.01sā9999min (adjustable)
-
Trigger signal:
-
High level: 3.0ā24V
-
Low level: 0.0ā0.2V
-
Passive switch
-
-
Output capacity:
-
Up to 30V 5A DC or 220V 5A AC
-
-
Quiescent current: 15mA
-
Operating current: 50mA
-
Life: More than 100,000 cycles
-
Working temperature: -40 to +85°C
-
Size: 88 Ć 38 Ć 19mm
Selection of time interval:
On the OP/CL settings screen:
-
XXXX= 1ā9999 seconds -
XXX.X= 0.1ā999.9 seconds -
XX.XX= 0.01ā99.99 seconds -
XXXX= 1ā9999 minutes
Parameter setting:
-
OP: Power-on time
-
CL: Shutdown time
-
RUN: Number of cycles (1ā9999 or āā-ā for infinite loop)
To change:
-
Hold in SET to enter settings
-
Select working mode with UP/DOWN
-
Confirm with SET to proceed to parameter settings
-
Adjust each parameter with short/long press of UP/DOWN
-
Press STOP to switch between seconds and minutes
-
Press and hold SET to save and leave
Working modes:
-
P1: Triggers ā relay on (OP time) ā off
-
P2: Triggers ā relay on (OP) ā triggers during OP ā recalculation
-
P3: Triggers ā relay on (OP) ā new trigger ā reset
-
P4: Triggers ā waiting for OP ā relay on ā OP ready ā off
-
P5: Triggers ā OP on ā CL off ā cycle starts (number definable)
-
P6: Automatic cycle without trigger (OP + CL)
-
P7: Relay is kept active as long as the signal is present. In case of interruption, OP timer starts and relay is switched off.
Additional features:
-
Automatic sleep mode: Turns off LCD background after 5 minutes (can be enabled/disabled)
-
Relay function ON/OFF: STOP switches if relay should respond to conditions
-
Parameter review: Short press on SET shows current values
-
Display switching: In mode P5/P6, the display can switch between time and number of cycles